ABN-182 User’s Guide
10
4. set_nextboot
Function
name
set_nextboot
Description
1. Set Ethernet segment to normal mode or non -normal mode
when boot up next time
Format:
int set_nextboot (unsigned char mo de,unsigned char seg,unsigned char
proc_dev)//v1.04
Input:
1. mode:
1-1. SET_NB_NORMAL: set Ethernet segment to normal mode
1-2. SET_NB_NO_NORMAL: set Ethernet segment to non -normal mode.
2. seg:It assign which card in structure of card type to do set_nextboot
function.
3. proc_dev:
3-1. PROD_ABN182 :bypass card of abn182
Return: 0: return ok.
-1:return fail.